Revision No. Description Date Logged Status
064 Beta Test Comments v1.2.0.0 - Analysis Runs Should Provide Warning When Minimum End / Edge Distance is Violated 11/15/2007 v1.2.0.0
063 Beta Test Comments v1.1.5.0 - Incorrect DC2 and FWS Load Factors for STR1P 10/09/2007 v1.2.0.0
062 Beta Test Comments v1.1.5.0 - Oversize Hole Affects Minimum End Dist & Minimum Pitch 10/03/2007 v1.2.0.0
061 Designed splice shows web specification check failure 08/13/2007 open
060 Oversize Hole Affects Minimum End Distance and Minimum Pitch 06/19/2007 v1.2.0.0
059 Connection Type Bearing causes Crash when all output selected 04/25/2007 v1.2.0.0
058 Designed splice shows flange specification check failure 04/19/2007 v1.2.0.0
057 Problem with maximum gage calculation 03/08/2007 v1.2.0.0
056 Use Updated License File 02/01/2007 v1.2.0.0
055 BETA TEST COMMENT: Update SPLRFD to IVF 9.1 01/10/2007 v1.2.0.0
054 Update RUN.INI and HELP.INI files 12/08/2006 v1.2.0.0
053 Continue Input Range Checking for Remainder of Input Line After Error 09/25/2006 v1.2.0.0
052 Implement Oversize Holes 08/02/2006 v1.2.0.0
051 Convert DIGITAL/PADIGITAL to INTEL/PAINTEL 04/19/2006 v1.2.0.0
050 Eliminate requirement for permit load for pedestrian runs of the program 03/16/2006 v1.2.0.0
049 Eliminate the need for negative flexural capacity input for simple spans 03/16/2006 v1.2.0.0
048 Modify SPLRFD to use concurrent live load effects 03/16/2006 open
047 Combine pedestrian and non-pedestrian runs into a single program run 03/16/2006 v1.2.0.0
046 Program crash with 0.0 vehicle live load and pedestrian load 02/10/2006 v1.2.0.0
045 Implement changes to allow for input lines > 256 characters 11/03/2005 v1.2.0.0
044 Intel Visual Fortran program conversion 08/10/2005 v1.1.1.0
043 Update contact information in problem report file SplrfdRevReq.dot 08/10/2005 v1.1.0.0
042 Output values not aligned with column headings 07/19/2005 v1.1.0.0
041 Eliminate runtime warnings from example input files 03/31/2005 v1.1.0.0
040 Eliminate runtime warnings from example input files 03/08/2005 v1.1.0.0
039 Automatically update date and time for PD file 08/23/2004 v1.1.0.0
038 Add caption text to EngAsst image files 07/14/2004 v1.1.0.0
037 Check if any temporary files are made, and if so, create them in the TEMP directory instead 05/24/2004 v1.1.0.0
036  Increase left and right flange edge distances on FSB command 01/16/2004 v1.2.0.0
035 Add version resource information to DLL and EXE and retrieve it 12/05/2003 v1.1.0.0
034 Adding Long File Names To LRFD programs 11/17/2003 v1.1.0.0
033 Convert the SPLRFD Program to DLL 10/27/2003 v1.1.0.0
032 Specification Check Warnings 10/16/2003 v1.1.0.0
031 Repeated information in design trials tables 10/15/2003 v1.1.0.0
030 Update Engineering Assistant Configuration files for SPLRFD version1.0.3.0 10/02/2003 v1.1.0.0
029 Program crahses for the given Input 08/07/2003 v1.1.0.0
028 Investigated problem with 'design moment' distribution between DC1, DC2, FWS and Live Load 06/05/2003 v1.1.0.0
027 Compile SPLRFD v1.0 using Compaq Visual Fortran for Windows XP Compatibility 03/11/2003 v1.1.0.0
026 Question about web splice plate length in the analysis output 02/21/2003 v1.1.0.0
025 Remove references to SPLRFD.DBG from the User's Manua 11/04/2002 v1.1.0.0
024 SID command modification for APRAS 03/26/2002 v1.1.0.0
023 Provide default values for ETA of 1.0. Update the PD file and users manual 03/22/2002 v1.1.0.0
022 Investigate adding separate input for dynamic load allowance for P-82 vehicles as per SOL 431-01-07 10/26/2001 v1.1.0.0
021 Investigate why program prints a warning for the FSB command for non-staggered cases 09/26/2001 v1.1.0.0
020 Under certain circumstances number of bolts for flange splice is not a multiple of the number of gage lines 09/26/2001 v1.1.0.0
019 Investigate if program should indicate failure when absolute value of stress exceeds flexural resistance 09/26/2001 v1.1.0.0
018 Investigate if gage distance requirement should be changed to 24 times the thickness 09/25/2001 v1.1.0.0
017 Clarify the sign convention for shear in the User Manual 09/18/2001 v1.1.0.0
016 Investigate flange splice design moment to determine if it should be computed by subtracting the web design moment 09/18/2001 v1.1.0.0
015 Investigate why under certain conditions output does not include bearing information even when activated on OSC command. 09/15/2001 v1.1.0.0
014 Add input checks to verify edge and end distances consistency checks 07/13/2001 v1.1.0.0
013 AASHTO Section C6.13.6.1.4b  -  Revise program to calculate bolt bearing capacity  based on the inclined distance of the resultant bolt force. 05/08/2001 v1.1.0.0
012 DM-4 2000  -  Update factored bolt resistance calculation 05/03/2001 v1.2.0.0
011 Investigate gage distance code failure reported for staggered bolt patterns 05/03/2001 v1.1.0.0
010 Add a special copyright notice for beta test versions of the program. 02/15/2001 v1.1.0.0
009 Pause the program when the run is complete to prevent the DOS window from closing automatically 02/15/2001 v1.1.0.0
008 Activate additional compiler settings to prevent divide by zero errors 02/15/2001 v1.1.0.0
007 Revise design moment distribution between DC1, DC2, FWS and LL for specific input file run. 01/19/2001 v1.1.0.0
006 Support Windows 2000 01/11/2001 v1.1.0.0
005 Permit input files to be stored in other directories than the program files. 01/11/2001 v1.1.0.0
004 Update PENNDOT's address for User Manual Chapter 9 & add contact person e-mail address 01/11/2001 v1.1.0.0
003 Use a different extension (other than .PDF) for parameter definition file 01/11/2001 v1.1.0.0
002 Support 4 digit years on output 09/24/1999 v1.1.0.0
001 Convert to Compaq Visual Fortran Compiler 09/24/1999 v1.1.0.0