This page was last updated on: May 10, 2010
Current Production Version 7.13.0.0
| Revision No. | Description | Date Logged | Status |
| 182 | Add the edit check for ADTT Year to avoid the "Divide by Zero" error which crashed the program. | 12/24/2009 | v7.13.0.0 |
| 181 | There appears to be an incorrect error check for the Distribution Factors with a “TTT” bridge type. Distribution factors don't need to be entered for the bridge type of "TTT". | 08/03/2009 | v7.13.0.0 |
| 180 | BAR7 Manual - Chapter 7 Example 5 pp 7-42 & 7-53. In example 5, the Lane, Moment distribution Factor, and Range of Steel Member Property card are incorrect. Also change text to improve readability.. | 07/21/2009 | v7.13.0.0 |
| 179 | Increase MAX_GIR_SECS four times to accommondate more sections. Revise the manual accordingly. | 04/07/2009 | v7.13.0.0 |
| 178 | Correct a typo in format (XXXDD) of the WF BEAM OR WEB PLATE DEPTH of Steel Member Properties card in Figure 5.1.6 (Input Form 6) of the User Manual. | 12/07/2009 | v7.13.0.0 |
| 177 | The program has been converted to Intel Visual Fortran compiler 10.1.013. | 12/06/2008 | v7.13.0.0 |
| 176 | Correct a typo of Live Load Item in the Help screen of Project tab in EngAsst. | 12/06/2008 | v7.13.0.0 |
| 175 | Add the skew correction factor for shear to account for increased shear due to skew as refer to the AASHTO LRFD Section 4.6.2.2.3c for bridge types of “CTB” and “GGG”. | 12/05/2008 | v7.13.0.0 |
| 174 | The allowable bending stress equation as listed in Tables 6.6.2.1-1 and 6.6.2.1-2 of the 1994, 2nd Edition (2000 Interim) AASHTO Manual for the Condition Evaluation of Bridges shall be used when checking the combined stress equation in AASHTO 10.36. Several new Items were added into Truss Member Properties card in Figure 5.1.5 (Input Form 5). This option is available when CORS in the Bridge Cross Section and Loading card is coded with “X”. | 09/25/2008 | v7.13.0.0 |
| 173 | Implement unreleased version of BSP v1.5.0.2, the release version of BSP is 1.3. | 10/15/2008 | v7.13.0.0 |
| 172 | Increase the Range of Steel Member (such as Built-up Girder) to 100. | 07/07/2008 | v7.13.0.0 |
| 171 | Add edit check for special live loads: you must have the truck load and the number of axles of this truck shall be between 2 and 80. | 06/06/2008 | v7.13.0.0 |
| 170 | Output truss member lengths so that users can verify that the truss model is correct. | 04/16/2008 | v7.13.0.0 |
| 169 | Revise the Truss geometry Images 2 and 3 in the Engineering Assistant (EngAsst) and Figure 5.11.1 (Truss Geometry) in the User Manual to clarify the meaning of H3 parameter. Add Figure 5.11.6 Truss Geometry (Example 4) to better explain the input of Truss Geometry. | 04/16/2008 | v7.13.0.0 |
| 168 | End of file error for TTT bridge type when running with standard live load groups. Blank input line at the end of the input file is required to successfully run the program. | 04/16/2008 | v7.13.0.0 |
| 167 | The program has been Incorporated the Gusset Plate Module of TRLRFD and added the ability of gusset plate analysis and rating utilizing Load Factor Rating (LFR) method. | 03/06/2008 | v7.13.0.0 |
| 166 | Live load codes 7 and 8 were added to the dropdown list for the “Live Load” Field of the “Project” tab in Engineering Assistant. | 11/09/2007 | v7.12.0.1 |
| 165 | Correct the shear capacity equation for Operating rating for slab bridges and T-beam bridges in Section 3.6.3 of the User’s Manual. | 11/06/2007 | v7.12.0.1 |
| 164 | Currently when a negative cover plate thickness (THICK) is entered to account for section loss and the corresponding field of cover plate width (WIDTH) is blank, the program does not calculate the section properties using the deteriorated section. Changed program to assume that if a negative thickness is entered, the section loss is considered over the entire flange width unless a cover plate width is entered. | 10/01/2007 | v7.12.0.1 |
| 163 | Allowed for a CBA enhancement that accepts user defined distribution factors. | 12/20/2007 | v7.12.0.1 |
| 162 | Resolve conflicting routine names between BAR7 and CBA code. | 12/20/2007 | v7.12.0.1 |
| 161 | Missing detailed output information for Lb and b’ when 1989 AASHTO Specification is used to compute the maximum strength of an unbraced section. | 09/06/2007 | v7.12.0.1 |
| 160 | For permit load compactness check, the beta factor for live load should be set 1.00 instead of 1.67. | 03/07/2007 | v7.12.0.1 |
| 159 | A problem has been corrected because the depth of section was not calculated correctly when a variable depth plate girder section (Type P) transitions into a wide flange beam (Type W). Modified the code to accommodate all combinations of steel member types and variable depths. | 03/05/2007 | v7.12.0.0 |
| 158 | Corrected the discrepancy in the printing of the message “NOTE: THIS MEMBER DOES NOT HAVE ALL SECTIONS QUALIFIED AS COMPACT SECTIONS. THEREFORE, EVEN …” between simple spans or a continuous span. | 03/02/2007 | v7.12.0.0 |
| 157 | Corrected the signs of the MU values at some of the brace points. | 03/02/2007 | v7.12.0.0 |
| 156 | Corrected the value being reported for the MR at that section when reviewing the detailed output for a specific section of a continuous girder. | 02/27/2007 | v7.12.0.0 |
| 155 | Modified the program to print code 1 for negative moment impact factor at a point with negative moment. | 02/26/2007 | v7.12.0.0 |
| 154 | When running a job with additional section properties analysis points added, the output is reporting this point twice in the tables of section properties. Added a check for duplicate analysis points and skipped printing those points. | 02/23/2007 | v7.12.0.0 |
| 153 | Modified the program to use M1/M2 ratio based on the span 2 unbraced length when analyzing the point at the end of the span 2 and to use M1/M2 ratio based on the span 3 unbraced length when analyzing the point at the beginning of the span 3. | 01/17/2007 | v7.12.0.0 |
| 152 | An input check was added and an error message is printed if more than 3 floorbeams are entered. | 01/07/2007 | v7.12.0.0 |
| 151 | The program has been enhanced to calculate correctly the moment capacity of a reinforced concrete T-beam when the area of compression reinforcement is equal to (or close to equal to) the area of tension reinforcement in the beam. | 11/07/2006 | v7.12.0.0 |
| 150 | The program
has been enhanced to compute section properties on both sides of the cutoff
for the purpose of analyzing and rating each section. Previously, BAR7
picked the section properties that had the less moment capacity and used
those properties for the rating calculations. Please note that for the
purpose of stiffness and determining the reactions, moments, shears,
deflections, and rotations, the BAR7 process does not change and it will
pass the appropriate moment of inertia to CBA. |
11/07/2006 | v7.12.0.0 |
| 149 | The Live Load code of “9” should not be a valid code according to the documentation. In case there may be some old input files with live load code equal to “9”, the “9” will be interpreted as number of special live loads equal to one. | 07/13/2006 | v7.12.0.0 |
| 148 | When using BAR7.11.0.9 through Engineering Assistant, the “TrussMem” tab shows errors. | 07/12/2006 | v7.12.0.0 |
| 147 | Use CBA to calculate all effects for intermediate analysis points instead of using the interpolation routines. Eliminate the XMERGEB routine and all the various interpolation routines. | 03/28/2006 | v7.12.0.0 |
| 146 | A problem has been corrected where the input variables for the FY in the top and bottom flanges of a stringer were not being used properly. | 04/27/2006 | v7.12.0.0 |
| 145 | A problem has been corrected where the program was reporting invalid section properties at all but the first location when analyzing stringers at multiple locations. | 03/08/2006 | v7.12.0.0 |
| 144 | Corrected the bottom flange angle vertical and horizontal leg dimensions in the sketch for the built-up section in the EngAsst. Previously, this sketch for built-up section was not consistent with the sketch on Page 5-55 in the User’s Manual. | 03/08/2006 | v7.12.0.0 |
| 143 | Provide a way for BAR7 to test the features of CBA Revision Request 018. This allows for the CBA module to accept the name of a temporary output file for the Standard CBA Output. | 03/03/2006 | v7.12.0.0 |
| 142 | Engineering Assistant will not allow negative or alphanumeric values to be entered into various code locations. | 03/02/2006 | v7.12.0.0 |
| 141 | A cross check error was fixed in the program when the maximum number (i.e. 5) of different Floorbeam brace point spacings or stiffener spacings was entered. | 03/02/2006 | v7.12.0.0 |
| 140 | The program has been converted to Intel Visual Fortran compiler v9.1. | 03/04/2006 | v7.12.0.0 |
| 139 | When H20 truck lane loading governs, the Critical Rating will sometimes be greater than the POS MOM Rating shown on the Load Rating summary page. | 09/29/2005 | v7.11.0.9 |
| 138 | Problem caused abnormal program termination when run using the Engineering Assistant or Engineering Manager GUI. | 09/06/2005 | v7.11.0.9 |
| 137 | Invalid truss panel type abnormally terminates the program. | 09/02/2005 | v7.11.0.9 |
| 136 | Special Live Loads maximum number of axles increased from 24 to 80 axles. | 09/01/2005 | v7.11.0.9 |
| 135 | Change the BAR7 User's Manual to show 13.68 kips for the first axle of the ML-80 load. | 05/17/2005 | v7.11.0.8 |
| 134 | Add a check to require non-zero value to be entered for area of longitudinal reinforcement when running a continuous composite girder. | 05/03/2005 | v7.11.0.8 |
| 133 | Change the effect of input variable (ENDPAN) to act as a switch to determine which AASHTO equation to use when calculating the shear in the end panel. | 05/03/2005 | v7.11.0.8 |
| 132 | .Add a new input variable (HYB) to the Project Identification to act as a switch to determine which AASHTO equation to use when calculating the shear in the end panel. | 05/03/2005 | v7.11.0.8 |
| 131 | Error when entering a lane load via special live load input for a truss. | 03/22/2005 | v7.11.0.8 |
| 130 | The program is modified to run as a Windows Dynamic Link Library (DLL). | 01/05/2005 | v7.11.0.8 |
| 129 | Add an input check and print an error message if the girder brace point spacing is greater than the span length. | 11/18/2004 | v7.11.0.6 |
| 128 | Selectively disallow the shear rating in the end panel from governing the rating in that section. | 11/18/2004 | v7.11.0.6 |
| 127 | Incorrect live load factors for floorbeams when wheel loads fall outside the floorbeam supports. | 10/20/2004 | v7.11.0.6 |
| 126 | BAR7 prints asterisks for some of the Girder Fatigue Details when running with Output Option 6. | 09/24/2004 | v7.11.0.6 |
| 125 | For reinforced concrete beam sections, add a way to describe a beam with different amounts and location of flexural reinforcement as a function of length. | 09/20/2004 | Open |
| 124 | On the Girder Fatigue Detail input, fatigue detail categories BP and EP, equivalent to B' and E', have been added to work around an issue with Engineering Dataset Manager. | 09/07/2004 | v7.11.0.6 |
| 123 | BAR7 appears to be calculating the Load Factor concrete deck rating factor incorrectly. | 08/27/2004 | v7.11.0.6 |
| 122 | Increase the size limit for the length of file names so that extra long file names (more than 100 characters) may be used. | 08/25/2004 | v7.11.0.6 |
| 121 | Correct a problem where a Type GFF structure with more than fourteen floorbeams caused an abnormal termination. | 08/24/2004 | v7.11.0.6 |
| 120 | Users Manual Correction, Page 1-2. Change "Fifteenth Edition, 1996" to "Fifteenth Edition, 1992". | 08/24/2004 | v7.11.0.6 |
| 119 | Enhance BAR7 to include multi-span continuous concrete T-beam and slab type structures. Allow Concrete Member Properties to vary based on ranges similar to the Steel Member | 05/04/2004 | Open |
| 118 | Clarify Description of DL2 in Chapter 5 of the User Manual | 004/30/2004 | v7.11.0.6 |
| 117 | Correct a problem where a Type GFS structure with no slab and very small stringers plus multiple stringerspans and multiple live loads caused an abnormal termination. | 004/29/2004 | v7.11.0.6 |
| 116 | Add a warning message to clarify the situation where the user enters a shear distribution factor and designates that there is only one stringer and it is an interior stringer. The program will use the inputted value instead of the value calculated based on the interior stringer's spacing. | 04/22/2004 | v7.11.0.6 |
| 115 | For the detailed rating output option, print "N/A" for values that do not apply rather than 999.99. Also print 999.99 for very large rating factors over 1000. | 03/17/2004 | v7.11 |
| 114 | Add a warning when the number of brace point spaces for a continuously braced top flange is entered as zero. Assume that there is one space. | 02/17/2004 | v7.11 |
| 113 | When printing section properties, allow for larger top and bottom section modulii so that the numbers do not run together. | 02/17/2004 | v7.11 |
| 112 | For a multispan girder where the section properties within each span are homogeneous, print out the span number that corresponds to each table of section properties on the output. | 02/17/2004 | v7.11 |
| 111 | Correct an error where the output table of Flexural Stresses - Slab was not being printed when 8 was entered for the OUTPUT option. | 002/17/2004 | v7.11 |
| 110 | Correct the calculation of the plastic neutral axis and moment capacity for composite floorbeams. The program erroneously used the actual index for the floorbeam (1, 2 or 3) instead of the floorbeam no. (span location) when accessing the effective slab width. | 002/17/2004 | v7.11 |
| 109 | For the detailed rating output option, for a non-composite section, print "N/A" for values that only apply to composite sections. Also print "N/A" for composite negative moment values when no reinforcement is input. | 002/17/2004 | v7.11 |
| 108 | For the detailed rating output option, for each section description, clarify whether GIRDER SPAN, FLOORBEAM NO. or STRINGER SPAN instead of the generic SPAN/FLOORBEAM. | 002/17/2004 | v7.11 |
| 107 | For the detailed rating output option, print the total factored and unfactored moments and shears for each of the four analysis cases. | 002/17/2004 | v7.11 |
| 106 | Use the sign (+ or -) of the LL+I moment instead of the total moment at a section when determining which LL+I section properties to use when calculating moment capacity or allowable stress. | 002/17/2004 | v7.11 |
| 105 | Correct the calculation of the radius of gyration about the Y-Y axis for a T-section in the compression flange of a built-up section. Neglect the segment of the web from the compression flange to the last hole. | 002/17/2004 | v7.11 |
| 104 | Bridge type GGF. Recalculate section properties after determining critical girder so that the proper effective slab width is used. | 02/17/2004 | v7.11 |
| 103 | Check for symmetry when choosing the format for printing out section properties (uniform section vs. section properties at each analysis point). | 011/05/2003 | v7.11 |
| 102 | Do not assume lane loading will not govern. Bridge type FSS may need lane load. | 09/25/2003 | v7.11 |
| 101 | Provide an input edit check for truss problems so that counters are not allowed for multi-span trusses | 06/13/2003 | v7.11 |
| 100 | Provide an input edit check for truss problems so that if H1 is not entered when needed, it is an error | 06/13/2003 | v7.11 |
| 099 | Eliminate the NaN error associated with the output from some Truss types | 05/05/2003 | v7.11 |
| 098 | Add a printout of the calculated distribution factors for concrete bridge types | 05/07/2003 | v7.11 |
| 097 | Add printout of brace point locations to Output Option A when a section is at a brace point | 05/13/2003 | v7.10a |
| 096 | Correct error with the rating of positive moment composite sections such that the b'/t limit is not used | 05/16/2003 | v7.10a |
| 095 | Correction to the input edit check for the HINGE AT location not on a support (end of span) | 05/13/2003 | v7.10a |
| 094 | Skip comment lines ("*" in column 1) when reading a special live load from a separate special live load file. | 04/14/2003 | v7.10 |
| 093 | Correction to the calculation of floorbeam weight. Range length wrong for the first main range when overhang | 04/14/2003 | v7.10 |
| 092 | Add an input error check for when stringer/girder locations are unsymmetrical | 04/08/2003 | v7.10 |
| 091 | Use the clear depth instead of the total depth to calculate the area of the web when computing shear stresses | 04/08/2003 | v7.10 |
| 090 | Add an output Note stating that the program does not check stiffener spacings against AASHTO criteria | 04/04/2003 | v7.10 |
| 089 | Use 1983 AAHSTO 3.23.4.3 to calculate the moment distribution factor for type CPL instead of 1996 AAHSTO | 03/17/2003 | v7.10 |
| 088 | Rearrange the output of default values into the order in which they were entered | 03/11/2003 | v7.10 |
| 087 | Add new bridge type TTT to analyze a truss only - no floorbeam or stringers. Changes made to User's Manual | 02/26/2003 | v7.10 |
| 086 | Reverse the change made in Revision 74. Do not Treat diagonal of truss panel types 1-4 (end panels) as either top or bottom chord when analyzing for lane load | 02/21/2003 | v7.10 |
| 085 | Reverse the change made in Revision 4. Do not allow stirrups for slab type bridges (CSL) | 02/11/2003 | v7.10 |
| 084 | Allow more than 5 spans for a continuous truss. Limit is 15 spans, same as for girders. Limit of 99 panels still applies and should govern the overall size of the structure | 01/29/2003 | v7.10 |
| 083 | Fix 'Error opening temporary output file' condition that was occurring when running via EngMgr with a special live load file | 01/23/2003 | v7.10 |
| 082 | Check for Type FSS when generating APRAS 'One-line' output so that fictitious Girder ratings are skipped | 01/16/2003 | v7.10 |
| 081 | Send input error messages to standard output file even when APRAS 'One-line' output option 'P' is selected | 01/16/2003 | v7.10 |
| 080 | Correct a problem where Type FSS with floorbeam overhang causes BAR7 to crash or go into a loop | 01/13/2003 | v7.10 |
| 079 | Correct a problem where erratic results (very large ratings or *****) were being printed for certain special loads | 01/10/2003 | v7.10 |
| 078 | Correction to the calculation of effective slab width for the critical girder of bridge type GGF | 07/17/2002 | v7.10 |
| 077 | Correction to the calculation of moment of inertia for a composite section when the neutral axis is above the bottom of the slab. The area of concrete below the neutral axis should be neglected | 07/11/2002 | v7.10 |
| 076 | Change ML80 & TK527 loadings as per PUB 238, page IP 03-2. Also use this same methodology for special live loads that have 3% INCR | 05/31/2002 | v7.10 |
| 075 | Add a check for an unexpected end-of-file and print out an informative error message | 04/25/2002 | v7.10 |
| 074 | Treat diagonal of truss panel types 1-4 (end panels) as either top or bottom chord when analyzing for lane load | 04/09/2002 | v7.10 |
| 073 | Correction to Revision 71 and a problem with analyzing 15 stringers | 02/19/2002 | v7.10 |
| 072 | Correction to the change where Uplift is not to be reported for stringers when type is GFS (Revision 43). Allow the uplift to be reported if the type is TFS or FSS | 02/13/2002 | v7.10 |
| 071 | Correct calculations to use appropriate stringer section properties based on stinger span. This is because the effective slab width may now be different between spans | 02/13/2002 | v7.10 |
| 070 | Add an input error message to catch if someone tries to enter brace points or stiffeners for a stringer | 02/13/2002 | v7.10 |
| 069 | Refine the messages in the detailed output to differentiate between the B'/T check for compactness and the B'/T check used to warn of possible constructability or fatigue problems | 02/04/2002 | v7.10 |
| 068 | Compute the allowable tension in truss members that have moment of inertia equal to zero and only skip the calculation of allowable compression | 12/28/2001 | v7.10 |
| 067 | Refine the error message to better describe the situation when type GGF input is incorrect | 12/20/2001 | v7.10 |
| 066 | Provide an error message if a negative stringer location is entered when the OVERHANG is zero | 12/11/2001 | v7.10 |
| 065 | Allow a cantilever floorbeam to be non-continuous, i.e., partial or no moment passed thru at the support | 12/11/2001 | Open |
| 064 | Add an input error edit check to flag an error if the truss "HINGE AT" joint designation on the Bridge Cross Section and Loading data is not at a support | 10/19/2001 | v7.10 |
| 063 | Add an input error edit check to flag an error if the accumulative sum of truss panel widths fall within 1/2" of the accumulative span lengths for each span | 10/19/2001 | v7.10 |
| 062 | Add a new live load posting vehicle TK527 | 10/16/2001 | v7.10 |
| 061 | Provide the capability to handle the situation where the deck is overhanging the girder with no cantilever or bracket on the floorbeam | 03/21/2001 | Open |
| 060 | Correct calculation of estimated fatigue life HS20 TRK STRESS for positive and negative live load plus impact moments | 02/28/2001 | v7.11.0.6 |
| 059 | Check provisions of AASHTO Equation (10-119) when rating unsymmetrical stiffened girders | 08/22/2000 | Open |
| 058 | Allow different gage distances for multiple special live loads and recalculate distribution factors for each load | 08/09/2000 | Open |
| 057 | Add a third option to LANES input for user to define a median barrier | 06/30/2000 | Open |
| 056 | Add new input items for single lane distribution factor and multi-lane distribution factors, moment and shear | 06/22/2000 | Open |
| 055 | Add two new codes to the LIVE LOAD field on the Project Identification as follows: I - consider HS20 and ML80 loadings and J - consider HS25, IML and ML80 loadings. | 06/22/2000 | v7.11.0.6 |
| 054 | Provide analysis for a special live load in one lane and a specified "other" vehicle(s) in remaining lane(s), where "other" vehicle(s) are defined through the LIVE LOAD field on the Project Identification | 06/22/2000 | Open |
| 053 | Add new input items to make use of CBA library to allow for user supplied or non-uniform dead loads | 06/09/2000 | Open |
| 052 | Add new input items to make use of BSPS library to allow for non-standard beam sections (deteriorated or patched) | 06/09/2000 | Open |
| 051 | Incorporate CBA and BSPS libraries to be used as engines in BAR7. Rename BAR7 elements to avoid duplicate names with CBA or BSPS | 06/09/2000 | v7.11 |
| 050 | Break code into separate files for each routine. Put COMMON blocks into INCLUDE statements | 06/09/2000 | v7.11 |
| 049 | Incorporate new equation for Cb for braced sections - AASHTO 10.48.4.1 | 10/23/1998 | Open |
| 048 | Use Safe Load Capacity (SLC) ratings if they exist for an APRAS/ABAS job | 09/27/2001 | v7.10 |
| 047 | Correct shear strength calculation for interior panels of transversely stiffened hybrid girders | 09/05/2001 | v7.10 |
| 046 | Correct shear strength calculation for end panels of transversely stiffened girders | 09/05/2001 | v7.10 |
| 045 | Correct calculation of allowable compression in an eccentrically loaded truss member using the combined stress formula | 06/26/2001 | v7.10 |
| 044 | Revise User's Manual pages 194, 195 and 209 to reflect that output values are not multiplied by PTF | 02/28/2001 | v7.10 |
| 043 | Do not check for uplift on stringers of a GFS type bridge | 01/12/2001 | v7.10 |
| 042 | Compile using Compaq Visual Fortran | 12/29/2000 | v7.10 |
| 041 | Add a check to allow multiple negative stringer locations when computing main girder effective slab width | 10/18/2000 | v7.10 |
| 040 | Add a check to trap an invalid (negative) square root argument when the combined stress formula has inappropriate input values for calculating end eccentricity | 07/13/2000 | v7.10 |
| 039 | Correct an error so that dead loads are not redistributed to the wrong panel joints when panel type 7 follows panel type 8 or panel 8 follows panel 7 and there is a vertical missing between panels | 07/13/2000 | v7.10 |
| 038 | Add a check for VERTICAL POST = 'N' in the truss geometry allowable panel combinations to allow the panel type combination 7 followed by 8 when the vertical is removed. Change the check to allow truss panel type 7 to follow panel type 8 when the appropriate vertical is missing, depending upon whether the load crosses the upper (deck truss) or lower (thru truss) chords. With both verticals present, it will still be an error because it is indeterminate | 07/07/2000 | v7.10 |
| 037 | Add an input error edit check to flag an error if the sum of truss panel widths for each span do not equal the span length | 06/07/2000 | v7.10 |
| 036 | Add an input error edit check to flag an error if the Deck Width is less than the Roadway Width | 05/16/2000 | v7.10 |
| 035 | When calculating the ratings for each of the four cases:
1. Maximum positive moment & simultaneous shear 2. Maximum negative moment & simultaneous shear 3. Maximum positive shear & simultaneous moment 4. Maximum negative shear & simultaneous moment Do not consider the ratings from cases 1 and 2 when determining the controlling shear ratings and do not consider the ratings from cases 3 and 4 when determining the controlling moment ratings |
05/16/2000 | v7.10 |
| 034 | Correct an error for Bridge Type "EIB", shored versus unshored construction. For shored construction, use DL2 properties for DL1 stresses and rating calculations, but do not use DL2 depth to compute shear rating. | 05/16/2000 | v7.10 |
| 033 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because of either of the above two items | 05/15/2000 | v7.10 |
| 032 | Do not allow a built up section to be compact because of holes in the tension flange as per the 2000 Interims of AASHTO Standard Specifications | 05/15/2000 | v7.10 |
| 031 | Do not allow a longitudinally stiffened section to be compact as per the 2000 Interims of AASHTO Standard Specifications | 05/15/2000 | v7.10 |
| 030 | Check for web buckling based on whether the section is unstiffened, transversely stiffened or longitudinally stiffened | 05/10/2000 | v7.10 |
| 029 | Use 15400/fy0.5 for the web thickness check to determine whether or not a section is braced non-compact | 05/10/2000 | v7.10 |
| 028 | Print a warning in the detailed output (OUTPUT code is "A") if the section does not meet compression flange projection requirement (B'/T is greater than allowable), but do not use this to determine Braced vs. Unbraced | 05/05/2000 | v7.10 |
| 027 | Print a message in the detailed output (OUTPUT code is "A") if the section is unbraced non-compact because the unbraced length is greater than the allowable spacing of lateral bracing in the compression flange | 05/05/2000 | v7.10 |
| 026 | Continue to print a warning in the detailed output (OUTPUT code is "A") if the section does not meet web buckling criteria (DC/TW is greater than MAX DC/TW), but do not use this to determine Braced vs. Unbraced | 05/05/2000 | v7.10 |
| 025 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because LB/RY is greater than the allowable maximum | 05/03/2000 | v7.10 |
| 024 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because 2DCP/TW + 9.35(B'/T) is greater than the allowable maximum | 05/03/2000 | v7.10 |
| 023 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because 2DCP/TW is greater than the allowable maximum | 05/03/2000 | v7.10 |
| 022 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because DP/D' is greater than 5 for a positive moment composite section | 05/03/2000 | v7.10 |
| 021 | Correct an error in the detailed output (OUTPUT code is "A"). When printing the Area, M of I and C Bot properties for LL+I, check for + or - LL moment and print properties accordingly | 05/02/2000 | v7.10 |
| 020 | Add a new input item for Integral Wearing Surface at the end of the Concrete Member Properties data. The default value is 0.5 inches | 04/13/2000 | v7.10 |
| 019 | Correct an error so that Flexural Stresses - Slab are printed for composite stringers | 04/03/2000 | v7.10 |
| 018 | Add a new input item for Integral Wearing Surface at the end of the Concrete Member Properties data. The default value is 0.5 inches | 04/03/2000 | v7.10 |
| 017 | Correct an error so that Flexural Stresses - Slab are printed for composite stringers | 04/03/2000 | v7.10 |
| 016 | Increase the space between the output fields C BOT and S TOP when printing section properties | 04/03/2000 | v7.10 |
| 015 | Correct an error so that a decimal point can be explicitly entered for the axle distance of a special live load | 04/03/2000 | v7.10 |
| 014 | Add an input error edit check to flag an error if no angle data is entered when the steel member type is "B" | 01/20/2000 | v7.10 |
| 013 | Correct an error so that the appropriate sign (+ or -) is applied to the Overload Moment Strength on the output | 01/18/2000 | v7.10 |
| 012 | Correct an error in the calculation of the distance measured from the support within which the allowable steel stresses in bent up bars should be considered for a concrete structure. The distance to the c.g. of tension reinforcement, d, that was entered in inches needed to be converted to feet | 12/10/1999 | v7.10 |
| 011 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because B'/T is greater than the maximum allowable B'/T | 12/08/1999 | v7.10 |
| 010 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because it does not have a constant web depth | 12/08/1999 | v7.10 |
| 009 | Print a message in the detailed output (OUTPUT code is "A") if the section is not compact because Fy is > 50 ksi for a positive moment composite section | 12/08/1999 | v7.10 |
| 008 | Print the value of DP/D' in the detailed output (OUTPUT code is "A") | 12/08/1999 | v7.10 |
| 007 | Correct an error in the calculation of the plastic moment capacity for a built up section. When the plastic neutral axis falls in the vertical part of the bottom angles, the portion of the web above the neutral axis had the wrong sign. Hence, the Mu was being calculated incorrectly | 10/20/1999 | v7.10 |
| 006 | Add an input error edit check to flag an error if the moment distribution factor is not entered when the CONT code for stringer span lengths is "C" | 10/14/1999 | v7.10 |
| 005 | Add a new bridge type "CPL" to analyze precast slab type bridges | 10/08/1999 | v7.10 |
| 004 | Allow slab type bridges (CSL) to include shear capacity of stirrup reinforcement for load factor ratings | 09/28/1999 | v7.10 |
| 003 | Correct an error where 2.375 was being printed as the default input value of UNIT WEIGHT DECK CONC | 06/08/1999 | v7.10 |
| 002 | Increase the size of some of the output fields to avoid printing ****** for truss output items | 04/13/1999 | v7.10 |
| 001 | Increase the number of truss panels allowed from 60 to 99 | 04/13/1999 | v7.10 |